ZHAO Ming-xi, LI Ruo-yi, SUN Jian-hua, SU Long-xiang, LI Qi, LI Zun-zhu, MA Hong-ming, CUI Wen-bo, LUO Hong-bo, ZHOU Xiang. Application of Ultrasound-guided Peripheral Arterial Puncture in Severe Patients with Coronavirus Disease 2019 Under Three-level Protection[J]. Medical Journal of Peking Union Medical College Hospital, 2021, 12(1): 44-48. DOI: 10.12290/xhyxzz.20200209
Citation: ZHAO Ming-xi, LI Ruo-yi, SUN Jian-hua, SU Long-xiang, LI Qi, LI Zun-zhu, MA Hong-ming, CUI Wen-bo, LUO Hong-bo, ZHOU Xiang. Application of Ultrasound-guided Peripheral Arterial Puncture in Severe Patients with Coronavirus Disease 2019 Under Three-level Protection[J]. Medical Journal of Peking Union Medical College Hospital, 2021, 12(1): 44-48. DOI: 10.12290/xhyxzz.20200209

Application of Ultrasound-guided Peripheral Arterial Puncture in Severe Patients with Coronavirus Disease 2019 Under Three-level Protection

Funds: 

Public Safety Risk Prevention and Control and Emergency Technical Equipment National Key Research and Development Program 2020YFC0861000

Medical and Health Science and Technology Innovation Project of Chinese Academy of Medical Sciences 2020-I2M-CoV19-001

More Information
  • Received Date: August 02, 2020
  • Accepted Date: September 26, 2020
  • Issue Publish Date: January 29, 2021
  •   Objective  To explore the application of ultrasound-guided arterial line placement in severe patients with COVID-19.
      Methods  From February to April 2020, we retrospectively collected and analyzed the clinical data of critical patients with COVID-19 with an indwelling peripheral arterial catheter treated by the medical team of Peking Union Medical College Hospital. Patients with ultrasound-guided peripheral arterial catheterization were taken as the study group, while patients whose arterial catheter was placed by traditional palpation were taken as the control group. The puncture condition and complication rate were compared between the two groups.
      Results  A total of 60 severe patients with COVID-19 who met the inclusion and exclusion criteria were enrolled in this study. There were 30 cases in the study group and 30 cases in the control group. In the study group, the success rate of the first catheterization of the peripheral artery (63.3% vs. 26.7%) and the total puncture success rate [(79.43± 25.79)% vs. (53.07±30.21)%] were higher than those in the control group (all P < 0.05), the puncture times(1.43±0.56 vs. 2.50±1.28) were less than those of the control group (P < 0.05). The rates of 24-hour disuse (6.7% vs. 30.0%), local hematoma (10.0% vs. 36.7%), occlusion, and tortuous (3.3% vs. 40.0%) in the study group were lower than those in the control group (all P < 0.05).
      Conclusion  Under the three-level protection, ultrasound-guided arterial catheter placement for severe patients with COVID-19 can improve the success rate of catheter placement, reduce puncture times, and reduce the incidence of complications.
  • [1]
    国家中医药管理局办公室中华人民共和国国家卫生健康委员会办公厅.新型冠状病毒肺炎诊疗方案(试行第八版)[J].中国医药, 2020, 15: 1494-1499. https://www.cnki.com.cn/Article/CJFDTOTAL-ZGYG202010002.htm

    General Office of National Health Commission of the People's Republic of China. Office of National Administration of Traditional Chinese Medicine, Diagnosis and treatment of corona virus disease-19(8th trial edition)[J], Zhongguo Yi Yao, 2020, 15:1494-1499. https://www.cnki.com.cn/Article/CJFDTOTAL-ZGYG202010002.htm
    [2]
    尹万红, 康焰.新型冠状病毒肺炎急性呼吸窘迫综合征的血流动力学治疗[J].协和医学杂志, 2020, 11: 518-521. DOI: 10.3969/j.issn.1674-9081.2020.05.004

    Yin WH, Kang Y. Hemodynamic therapy for COVID-19 patients with acute respiratory distress syndrome[J]. Xie He Yi Xue Za Zhi, 2020, 11: 518-521. DOI: 10.3969/j.issn.1674-9081.2020.05.004
    [3]
    Shiloh AL, Savel RH, Paulin LM, et al. Ultrasound-guided catheterization of the radial artery: a systematic review and meta-analysis of randomized controlled trials[J]. Chest, 2011, 139: 524-529. DOI: 10.1378/chest.10-0919
    [4]
    孙建华, 刘大为, 王小亭, 等.超声引导下桡动脉置管的应用进展[J].中国实用护理杂志, 2016, 32: 1997-2000. DOI: 10.3760/cma.j.issn.1672-7088.2016.25.022

    Sun JH, Liu DW, Wang XT, et al. Development of application research of ultrasound guided radial artery cannulation[J]. Zhongguo Shi Yong Hu Li Za Zhi, 2016, 32: 1997-2000. DOI: 10.3760/cma.j.issn.1672-7088.2016.25.022
    [5]
    Tang L, Wang F, Li Y, et al. Ultrasound guidance for radial artery catheterization: an updated meta-analysis of randomized controlled trials[J]. PLoS One, 2014, 9: e111527. DOI: 10.1371/journal.pone.0111527
    [6]
    姜利, 潘纯, 桑岭, 等.重症新型冠状病毒肺炎管理专家推荐意见[J].中华重症医学电子杂志, 2020, 6: 1-11. https://www.cnki.com.cn/Article/CJFDTOTAL-ZZYD202001001.htm

    Jiang L, Pan C, Sang L, et al. Expert recommendations for management of severe COVID-19[J]. Zhonghua Zhong Zheng Yi Xue Dian Zi Za Zhi, 2020, 6: 1-11. https://www.cnki.com.cn/Article/CJFDTOTAL-ZZYD202001001.htm
    [7]
    Bhattacharjee S, Maitra S, Baidya DK. Comparison between ultrasound guided technique and digital palpation technique for radial artery cannulation in adult patients: an updated meta-analysis of randomized controlled trials[J]. J Clin Anesth, 2018, 47: 54-59. DOI: 10.1016/j.jclinane.2018.03.019
    [8]
    Rath A, Mishra SB, Pati B, et al. Short versus long axis ultrasound guided approach for internal jugular vein cannulations: a prospective randomized controlled trial[J]. Am J Emerg Med, 2020, 4: 731-734. DOI: 10.1016/j.ajem.2019.06.010
    [9]
    Rodriguez-Niedenfuhr M, Vazquez T, Nearn L, et al. Variations of the arterial pattern in the upper limb revisited: a morphological and statistical study, with a review of the literature[J]. J Anat, 2001, 199: 547-566. DOI: 10.1046/j.1469-7580.2001.19950547.x
    [10]
    Scheer B, Perel A, Pfeiffer UJ. Clinical review: complications and risk factors of peripheral arterial catheters used for haemodynamic monitoring in anaesthesia and intensive care medicine[J]. Crit Care, 2002, 6: 199-204. DOI: 10.1186/cc1489
    [11]
    Lamperti M, Bodenham AR, Pittiruti M, et al. International evidence-based recommendations on ultrasound-guided vascular access[J]. Intensive Care Med, 2012, 38: 1105-1117. DOI: 10.1007/s00134-012-2597-x
    [12]
    王宁, 李民, 郭向阳, 等.超声引导桡动脉穿刺置管学习曲线的建立[J].中华医学教育杂志, 2016, 36: 295-299. DOI: 10.3760/cma.j.issn.1673-677X.2016.02.036

    Wang N, Li M, Guo XY, et al. The construction of learning curves for ultrasound-guide indwelling of radial artery catheters[J]. Zhonghua Yi Xue Jiao Yu Za Zhi, 2016, 36: 295-299. DOI: 10.3760/cma.j.issn.1673-677X.2016.02.036
  • Cited by

    Periodical cited type(3)

    1. 刘慧勤,任海涛,徐雁,高鑫雅,李玮,张杰文,关鸿志. AQP4-IgG阳性视神经脊髓炎谱系疾病的脑脊液细胞学特点. 中国神经免疫学和神经病学杂志. 2018(01): 6-10 .
    2. 梁文娜,李立芳. 鼠神经生长因子联合甲泼尼龙对格林-巴利综合征炎症反应的影响. 湖南师范大学学报(医学版). 2017(04): 64-67 .
    3. 王慧词,宋秀娟,张静,侯慧清,王维平,许艳秋,李令令. 脊髓空洞症合并吉兰-巴雷综合征一例. 脑与神经疾病杂志. 2016(04): 206-210 .

    Other cited types(0)

Catalog

    Article Metrics

    Article views (674) PDF downloads (24) Cited by(3)
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return
    x Close Forever Close