[1]
|
Haie-Meder C, Pötter R, Van Limbergen E, et al. Recommendations from Gynaecological (GYN) GEC-ESTRO Working Group (Ⅰ):concepts and terms in 3D image-based 3D treatment planning in cervix cancer brachytherapy with emphasis on MRI assessment of GTV and CTV[J]. Radiother Oncol, 2005, 74:235-245. doi: 10.1016/j.radonc.2004.12.015 |
[2]
|
Nath R, Anderson LL, Luxton G, et al. Dosimetry of interstitial brachytherapy sources:Recommendations of the AAPM Radiation Therapy Committee Task Group[J]. Med Phys, 1995, 22:209-234. doi: 10.1118/1.597458 |
[3]
|
Niroomand-Rad A, Blackwell CR, Coursey BM, et al. Radiochromic film dosimetry:Recommendations of AAPM Radiation Therapy Committee Task Group 55[J].Med Phys, 1998, 25:2093-2115. doi: 10.1118/1.598407 |
[4]
|
Herzen J, Todorovic M, Cremers F, et al. Dosimetric evaluation of a 2D pixelionization chamber for implementation in clinical routine[J]. Phys Med Biol, 2007, 52:1197-1208. doi: 10.1088/0031-9155/52/4/023 |
[5]
|
Saminathan S, Manickan R, Chandraraj V, et al. Dosimetric study of 2D ion chamber array matrix for the modern radiotherapy treatment verification[J]. J Appl Clin Med Phys, 2010, 11:116-127. doi: 10.1120/jacmp.v11i2.3076 |
[6]
|
Wolfsberger LD, Wagar M, Nitsch P, et al. Angular dose dependency of MatriXXTM and its calibration[J]. J Appl Clin Med Phys, 2010, 11:241-251. doi: 10.1120/jacmp.v11i1.3057 |
[7]
|
Dobler B, Streck N, Klein E, et al. Hybrid plan verification for intensity-modulated radiation therapy (IMRT) using the 2D ionization chamber array I'mRT MatriXX-a feasibility study[J]. Phys Med Biol, 2010, 55:N39-N55. doi: 10.1088/0031-9155/55/2/N02 |
[8]
|
Rickey DW, Sasaki D, Bews J.A quality assurance tool for high-dose-rate braehytherapy[J].Med Phys, 2010, 37:2525-2532. doi: 10.1118/1.3425786 |
[9]
|
Poppe B, Djouguela A, Blechschmidt A, et al. Spatial resolution of 2D ionization chamber arrays for IMRT dose verification:single-detector size and sampling step width[J]. Phys Med Biol, 2007, 52:2921-2935. doi: 10.1088/0031-9155/52/10/019 |
[10]
|
Poppe B, Mehran P, Kollhoff R, et al. Use of a two-dimensional ionisation chamber array for quality assurance at medical linear accelerators (in German)[J]. Z Med Phys, 2003, 13:115-122. doi: 10.1078/0939-3889-00151 |
[11]
|
Granero D, Pérez-Calatayud J, Jimeno J, et al. Design and evaluation of a HDR skin applicator with flattening filter[J]. Med Phys, 2008, 35:495-503. doi: 10.1118/1.2825622 |
[12]
|
Devic S, Tomic N, DeBlois F. Commissioning of brachytherapy TPS using EBT model GafChromic film[J]. Med Phys, 2009, 36:4323. doi: 10.1118/1.3244193/abstract |
[13]
|
Sorriaux J, Kacperek A, Rossomme S, et al. Evaluation of Gafchromic EBT3 films characteristics in therapy photon, electron and proton beams[J/OL]. Phys Med, 2012, http://dx.doi.org/10.1016/j.ejmp.2012.10.001. |
[14]
|
Yewondwossen M.Characterization and use of a 2D-array of ion chambers for brachytherapy dosimetric quality assurance[J]. Med Dosim, 2012, 37:250-256. doi: 10.1016/j.meddos.2011.09.004 |
[15]
|
Nath R, Anderson LL, Meli JA, et al. Code of practice for brachytherapy physics:report of the AAPM Radiation Therapy Committee Task Group No. 56. American Association of Physicists in Medicine[J]. Med Phys, 1997, 24:1557-1598. doi: 10.1118/1.597966 |
[16]
|
Venselaar J, Pêrez-Calatayud J, eds. A practical guide to quality control of brachytherapy equipment[M]. Brussels: ESTRO, 2004. |