IOL-Master与A型超声测量前房深度和眼轴长度比较及其相关性

徐海燕 金玉梅 李辉 胡伯越 姜茹欣

徐海燕, 金玉梅, 李辉, 胡伯越, 姜茹欣. IOL-Master与A型超声测量前房深度和眼轴长度比较及其相关性[J]. 协和医学杂志, 2012, 3(2): 200-203. doi: 10.3969/j.issn.1674-9081.2012.02.015
引用本文: 徐海燕, 金玉梅, 李辉, 胡伯越, 姜茹欣. IOL-Master与A型超声测量前房深度和眼轴长度比较及其相关性[J]. 协和医学杂志, 2012, 3(2): 200-203. doi: 10.3969/j.issn.1674-9081.2012.02.015
Hai-yan XU, Yu-mei JIN, Hui LI, Bo-yue HU, Ru-xin JIANG. Measurement of Anterior Chamber Depth and Axial Length with IOL-Master or Contact Ultrasonic Axial Scan: Comparison and Correlation[J]. Medical Journal of Peking Union Medical College Hospital, 2012, 3(2): 200-203. doi: 10.3969/j.issn.1674-9081.2012.02.015
Citation: Hai-yan XU, Yu-mei JIN, Hui LI, Bo-yue HU, Ru-xin JIANG. Measurement of Anterior Chamber Depth and Axial Length with IOL-Master or Contact Ultrasonic Axial Scan: Comparison and Correlation[J]. Medical Journal of Peking Union Medical College Hospital, 2012, 3(2): 200-203. doi: 10.3969/j.issn.1674-9081.2012.02.015

IOL-Master与A型超声测量前房深度和眼轴长度比较及其相关性

doi: 10.3969/j.issn.1674-9081.2012.02.015
详细信息
    通讯作者:

    李辉 电话:010-69156351, E-mail:huilixh1243@yahoo.com.cn

  • 中图分类号: R778

Measurement of Anterior Chamber Depth and Axial Length with IOL-Master or Contact Ultrasonic Axial Scan: Comparison and Correlation

More Information
  • 摘要:   目的  了解IOL-Master生物测量仪的准确性及可靠性。  方法  对北京协和医院92例患者161眼分别用IOL-Master和A型超声测量前房深度及眼轴长度, 同时用IOL-Master及电脑验光仪测量角膜曲率。  结果  IOL-Master和A型超声对前房深度的测量值分别为(2.94±0.19)和(2.77±0.13)mm, 两种方法比较差异有统计学意义(P < 0.001), 但两种测量方法无显著相关性(r=0.012, P>0.05)。IOL-Master和A型超声对眼轴长度的测量值分别为(24.10±2.36)和(23.91±2.13)mm, 两种方法比较差异有统计学意义(P < 0.01), 且两种测量方法具有显著相关性(r=0.983, P < 0.001)。IOL-Master和电脑验光仪测量角膜曲率分别为(44.38±1.66)和(44.12±1.62)D, 两种方法比较差异有统计学意义(P < 0.001)。  结论  IOL-Master与A型超声均可用于眼前节相关参数测量, 基于光学原理基础, IOL-Master测量前房深度和眼轴长度具有良好的可靠性和准确性, 为临床生物测量提供了新的选择。
  • [1] Gallego-Pinazo R, Pardo-López D, López-Prats MJ, et al. Evaluation of the improvement in sensitivity with the new IOL-Master[J]. Arch Soc Esp Oftalmol, 2011, 86:163-164. doi:  10.1016/j.oftal.2011.01.005
    [2] Fotedar R, Wang JJ, Burlutsky G, et al. Distribution of axial length and ocular biometry measured using partial coherence laser interferometry (IOL Master) in an older white population[J]. Ophthalmology, 2010, 117:417-423. doi:  10.1016/j.ophtha.2009.07.028
    [3] Kielborn I, Rajan MS, Tesha PM, et al. Clinical asseaament of the Zeiss IOL master[J]. J Cataract Refract Surg, 2003, 29:518-522. doi:  10.1016/S0886-3350(02)01819-9
    [4] Bai QH, Wang JL, Wang QQ, et al. The measurement of anterior chamber depth and axial length with the IOL Master compared with contact ultra sonic axial scan[J]. Int J Ophthalmol, 2007, 7:921-924. http://www.researchgate.net/publication/288914564_The_measurement_of_anterior_chamber_depth_andaxial_length_with_the_IOLMaster_compared_with_contact_ultrasonic_axial_scan
    [5] 李兴育, 赵云娥, 王勤美. IOL-Master测量眼人工晶状体计算公式准确性比较[J].临床眼科杂志, 2008, 16:389-392.
    [6] 方薇, 张健.国人正常眼轴老年白内障者人工晶状体屈光度计算公式的准确性研究[J].国际眼科杂志, 2009, 9:702-705. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=mzgjykzz200904029
    [7] 柏全豪, 刘珣, 李雪, 等. IOL-Master生物测量精确性和可重复性研究[J].中国实用眼科杂志, 2009, 27:848-852. http://www.cqvip.com/QK/91871A/20098/31402730.html
    [8] Suto C, Sato C, Shimanmura E, et al. Influence of the signal-to-noise ratio on the accuracy of IOL-Master measurements[J]. J Cataract Refract Surg, 2007, 33:2062-2066. doi:  10.1016/j.jcrs.2007.07.031
    [9] 贾力蕴, 王宁利, 梁远波, 等. IOL-Master与A型超声测量前房深度和眼轴的可重复性和相关性分析[J].中国实用眼科杂志, 2007, 25:63-65. http://d.wanfangdata.com.cn/Periodical/zgsyykzz200701018
    [10] Freeman G, Pesudovs K. The impact of cataract severity on measurement acquisition with the IOL Master[J]. Acta Ophthalmol Scaad, 2005, 83:439-442. doi:  10.1111/j.1600-0420.2005.00473.x
  • 加载中
计量
  • 文章访问数:  229
  • HTML全文浏览量:  83
  • PDF下载量:  9
  • 被引次数: 0
出版历程
  • 收稿日期:  2011-07-17
  • 刊出日期:  2012-04-30

目录

    /

    返回文章
    返回

    【温馨提醒】近日,《协和医学杂志》编辑部接到作者反映,有多名不法人员冒充期刊编辑发送见刊通知,鼓动作者添加微信,从而骗取版面费的行为。特提醒您,本刊与作者联系的方式均为邮件通知或电话,稿件进度通知邮箱为:mjpumch@126.com,编辑部电话为:010-69154261,请提高警惕,谨防上当受骗!如有任何疑问,请致电编辑部核实。谢谢!